DC Machines MCQs | DC Machines Multiple Choice Questions and Answers

(1) A shunt motor is fitted with a field regulator for speed control. For constant torque load, the speed will be minimum when the resistance of the regulator is
[A] 0Ω
[B] Infinite
[C] About 10Ω
[D] About 100Ω
Answer: 0Ω
(2) The resistance of the field regulator of a dc shunt motor is of order of
[A] 0.1Ω
[B] 1Ω
[C] 10Ω
[D] 100Ω
Answer: 100Ω
(3) The air gap between stator and armature of an electric motor is kept as small as possible
[A] To get a stronger magnetic field
[B] To improve the air circulation
[C] To reach a higher speed of rotation
[D] To make the rotation easier
Answer: To get a stronger magnetic field
(4) In a dc motor, unidirectional torque is produced with the help of
[A] Brushes
[B] Commutator
[C] End plates
[D] Both (a) and (b)
Answer: Both (a) and (b)
(5) In dc motor, the rotor is
[A] Welded to the shaft
[B] Keyed to the shaft
[C] Soldered to the shaft
[D] Both to the shaft
Answer: Keyed to the shaft
(6) The armature of a dc motor is laminated
[A] To reduce hysteresis loss
[B] To reduce eddy current loss
[C] To reduce the cost of core
[D] To reduce the mass of the armature
Answer: To reduce eddy current loss
(7) As the load on a dc shunt motor is increased, its speed
[A] Increases proportionately
[B] Remains constant
[C] Increases slightly
[D] Reduces slightly
Answer: Reduces slightly
(8) The speed of a series wound dc motor
[A] Can be controlled by shunt field regulator
[B] Can not be controlled by diverter
[C] Increases as flux decreases
[D] Increases as armature circuit resistance increases
Answer: Increases as flux decreases
(9) If the applied voltage to a dc shunt motor is halved and the load torque doubled, the armature current will be
[A] Unaltered
[B] Zero
[C] Doubled
[D] Halved
Answer: Doubled
(10) The starting resistance of a dc motor is usually
[A] Infinitely large
[B] Large
[C] About 100Ω
[D] Small
Answer: Small
(11) The back emf of a dc motor depends on
[A] Field flux
[B] Shape of conductors
[C] Type of slip rings
[D] Brush material
Answer: Field flux
(12) In a dc machine prominent and noisy blue and green sparks indicate
[A] Excessive brush wear
[B] Winding fault
[C] Worn out insulation
[D] None of these
Answer: Winding fault
(13) The flux is maximum in following unit of a dc motor
[A] Yoke leading end of pole shoe
[B] Trailing end of pole shoe
[C] Yoke
[D] Any of the above
Answer: Yoke
(14) In a dc motor, the flux leakage coefficient is typically
[A] 0.5 to 0.7
[B] 0.8 to 1.0
[C] 1.1 to 1.3
[D] 1.4 to 1.6
Answer: 1.1 to 1.3
(15) The current flowing in conductors of a dc motor is
[A] Ac
[B] Dc
[C] Ac as well as dc
[D] Transient
Answer: Ac
(16) The armature reaction in a dc motor is attributed to
[A] The effect of magnetic field set up by field current
[B] The effect of magnetic field set up by armature current
[C] The effect of magnetic field set up by back emf
[D] Copper losses in the armature
Answer: The effect of magnetic field set up by armature current
(17) In a dc motor if the brushes are given a backward shift, then
[A] Commutation improves and speed decreases
[B] Commutation is unaffected and speed increases
[C] Commutation improves and speed increases
[D] Commutation worsens and speed decreases
Answer: Commutation improves and speed increases
(18) The back emf Vb of a dc motor
[A] Opposes the applied voltage
[B] Assists the applied voltage
[C] Does not influence the applied voltage
[D] None of these
Answer: Opposes the applied voltage
(19) Current normally used to excite synchronous and d.c. generators is
[A] D.C
[B] A.C. single phase
[C] A.C. two phase
[D] A.C. three phase
Answer: D.C
(20) In case of a motor
[A] Only motor action takes place
[B] Motor action precedes generator action
[C] Generator action precedes motor action
[D] Both take place precedes simultaneously
Answer: Motor action precedes generator action

Take Mock Tests

Missiles Mock Test Start Test!
SSC MTS Mock Test Start Test
IBPS CLERK MOCK TEST Start Test
SSC MTS 2022 JULY 26 Shift 1 (ENGLISH) Start Test!
SSC GD Previous Year Paper 2021 Nov 17 Shift - I (Hindi) Start Test!
SSC CGL Tier - 1 PYP 2022 April 21 Shift- 1 (ENGLISH) Start Test!
MPSC PAPER I MOCK TEST 1 (ENGLISH) Start Test!
IB Security Assistant Mock test 1 (english) Start Test!
UP POLICE CONSTABLE MOCK TEST 1 Start Test!
DELHI POLICE CONSTABLE MOCK TEST 1 (HINDI) Start Test!