Two rectangular under-reinforced concrete beam sections X and Y are similar in all aspects except

Two rectangular under-reinforced concrete beam sections X and Y are similar in all aspects except

Q. Two rectangular under-reinforced concrete beam sections X and Y are similar in all aspects except that the longitudinal compression reinforcement in section Y is 10% more. Which one of the following is the correct statement? A. Section X has less flexural strength and is less ductile than section Y B. Section X has less […]

Two rectangular under-reinforced concrete beam sections X and Y are similar in all aspects except Read More »

A solid circular beam with radius of 0.25 m and length of 2 m is subjected to a twisting moment of 20 kNm

A solid circular beam with radius of 0.25 m and length of 2 m is subjected to a twisting moment of 20 kNm

Q. A solid circular beam with radius of 0.25 m and length of 2 m is subjected to a twisting moment of 20 kNm about the z-axis at the free end, which is the only load acting as shown in the figure. The shear stress component 𝑟𝑥𝑦 at Point ‘M’ in the cross-section of the

A solid circular beam with radius of 0.25 m and length of 2 m is subjected to a twisting moment of 20 kNm Read More »

A steel column of ISHB 350 @72.4 kg/m is subjected to a factored axial compressive load of 2000 kN

A steel column of ISHB 350 @72.4 kg/m is subjected to a factored axial compressive load of 2000 kN

Q. A steel column of ISHB 350 @72.4 kg/m is subjected to a factored axial compressive load of 2000 kN. The load is transferred to a concrete pedestal of grade M20 through a square base plate. Consider bearing strength of concrete as 0.45fck, where fck is the characteristic strength of concrete. Using limit state method

A steel column of ISHB 350 @72.4 kg/m is subjected to a factored axial compressive load of 2000 kN Read More »

A column of height h with a rectangular cross-section of size a×2a has a buckling load of P

A column of height h with a rectangular cross-section of size a×2a has a buckling load of P

Q. A column of height h with a rectangular cross-section of size a×2a has a buckling load of P. If the cross-section is changed to 0.5a × 3a and its height changed to 1.5h, the buckling load of the redesigned column will be (A) P/12                   (B) P/4                        (C) P/2                       (D) 3P/4 Ans: P/12

A column of height h with a rectangular cross-section of size a×2a has a buckling load of P Read More »

Each of the letters arranged as below represents a unique integer from 1 to 9. The letters are positioned in the figure such that

Each of the letters arranged as below represents a unique integer from 1 to 9. The letters are positioned in the figure such that

Q. Each of the letters arranged as below represents a unique integer from 1 to 9. The letters are positioned in the figure such that (A × B × C), (B × G × E) and (D × E × F) are equal. Which integer among the following choices cannot be represented by the letters

Each of the letters arranged as below represents a unique integer from 1 to 9. The letters are positioned in the figure such that Read More »

Which of the following function(s) is an accurate description of the graph for the range(s) indicated?

Which of the following function(s) is an accurate description of the graph for the range(s) indicated?

Q. Which of the following function(s) is an accurate description of the graph for the range(s) indicated? (i)      𝑦 = 2𝑥 + 4 for −3 ≤ 𝑥 ≤ −1 (ii)      𝑦 = |𝑥 − 1| for −1 ≤ 𝑥 ≤ 2 (iii)       𝑦 = ||𝑥| − 1| for −1 ≤ 𝑥 ≤ 2 (iv)       𝑦

Which of the following function(s) is an accurate description of the graph for the range(s) indicated? Read More »

Scroll to Top