The probability of a resistor being defective is 0.02. There are 50 such resistors in a circuit

The probability of a resistor being defective is 0.02. There are 50 such resistors in a circuit

Q. The probability of a resistor being defective is 0.02. There are 50 such resistors in a circuit. The probability of two or more defective resistors in the circuit (round off to two decimal places) is     . Solution: Probability of a resistor being defective (P) = 0.02 Number of resistors (n) = 50 Mean (λ)

The probability of a resistor being defective is 0.02. There are 50 such resistors in a circuit Read More »

The line currents of a three-phase four wire system are square waves with amplitude of 100 A. These three currents are phase shifted by 120°

The line currents of a three-phase four wire system are square waves with amplitude of 100 A. These three currents are phase shifted by 120°

Q. The line currents of a three-phase four wire system are square waves with amplitude of 100 A. These three currents are phase shifted by 120° with respect to each other. The rms value of neutral current is A. 0 A B. 100 A C. 3 A D. 1 A Ans: 100 A Solution:

The line currents of a three-phase four wire system are square waves with amplitude of 100 A. These three currents are phase shifted by 120° Read More »

DAILY CURRENT AFFAIRS

7 August 2023 Current Affairs – The Day’s Top News | GKSERIES

Current Affairs is the most important area in all competitive exams. But the difficulty level is very high. That’s why; many aspirants get confused, how to select Current Affairs for Preparation of Competitive Examination? In this Post, Daily Current Affairs 7 August 2023, we have tried to cover each and every point and also included all important facts from

7 August 2023 Current Affairs – The Day’s Top News | GKSERIES Read More »

A DC-DC buck converter operates in continuous conduction mode. It has 48 V input voltage, and it feeds a resistive load of 24 Ω

A DC-DC buck converter operates in continuous conduction mode. It has 48 V input voltage, and it feeds a resistive load of 24 Ω

Q. A DC-DC buck converter operates in continuous conduction mode. It has 48 V input voltage, and it feeds a resistive load of 24 Ω. The switching frequency of the converter is 250 Hz. If switch-on duration is 1 ms, the load power is (A) 6 W (B) 12 W (C) 24 W (D) 48

A DC-DC buck converter operates in continuous conduction mode. It has 48 V input voltage, and it feeds a resistive load of 24 Ω Read More »

Scroll to Top