JOIN ADRE 2.0 Telegram Group

Design of Masonry Structures Quiz | Design of Masonry Structures Objective Type Questions and Answers

Questions
21 For masonry built in 1:1:6 cement-lime-sand mix mortar or equivalent, the horizontal shear stress permissible on the area of a mortar bed joint is
A 0.15 MPa
B 0.125 MPa
C 0.1 MPa
D 0.075 MPa

Answer: 0.15 MPa
22 Consider the following statements:

1. Masonry in rich cement mortar though having good strength with high shrinkage is much liable for surface cracks.

2. Lime mortar possesses poor workability and poor water retentivity and also suffers high shrinkage.

3. Masonry in lime mortar has better resistance against rain penetration and is less liable to crack when compared to masonry in cement mortar.

Which of these statements are correct?
A 1,2 and 3
B 1 and 2
C 2 and 3
D 1 and 3

Answer: 1 and 3
Advertisement
Article and Schedule Quiz Start Test!

DOWNLOAD CURRENT AFFAIRS PDF FROM APP

23

Assertion A : For identical strength, a composite cement-lime mortar is preferred over cement mortar.

Reason R : Composite cement-lime mortar has higher drying shrinkage than cement mortar.

Select your answer based on the codes given below. Codes:
A Both A and R are true and R is the correct explanation of A.
B Both A and R are true but R is not a correct explanation of A.
C A is true but R is false.
D A is false but R is true.

Answer: A is true but R is false.
24 The basic stress in masonry units having height to width ratio of 1.5 may be increased by a factor of
A 1.2
B 1.4
C 1.6
D 2.0

Answer: 1.6
25 200 mm thick brick masonry wall made of modular bricks carries an axial load of 30 kN/m from wall above and an eccentric load of 20 kN/m from RCC floor acting at a distance of 47.5 mm from the centre line of the wall. The resultant eccentricity ratio is
A 0.090
B 0.095
C 0.100
D 0.105

Answer: 0.100
26 A 200 mm thick wall made of modular bricks is 5 m long between cross walls and 3.8 m clear height between RCC slabs at top and bottom. The slenderness ratio of the wall is
A 15
B 19
C 20
D 25

Answer: 15
27 Direct load carrying capacity of a brick masonry wall standing freely as against when it supports RC slab will be
A more
B less
C the same in both the cases
D 100%

Answer: less
28 The mortars used for masonry construction are classified based on strength in IS 2250 and IS 1905 according to their designations L1,L2, H1, H2, M, M2. The correct sequence of increasing order of their strengths is
A LLLZ.HLHI.MLMJ
B L2,L,,M2>Mi,H2)H,
C M,,M2, H,,H2,Li,L2
D L2,L,,M,,M2,H,,H2

Answer: L2,L,,M2>Mi,H2)H,
29 Consider the following statements: A high lime content in a composite cement-lime mortar results in

1. slow hardening.

2. quick setting.

3. weaker mortar.

Of these statements
A 2 and 3 are correct
B 1 and 2 are correct
C 1 and 3 are correctg
D 1, 2 and 3 are correct

Answer: 1 and 3 are correct
30 For strengthening a 50 m long and 5 m high straight compound wall built in brick work, which one of the following would be most suitable?
A providing buttresses at certain intervals
B providing a deeper foundation
C using a richer mortar
D using stronger bricks

Answer: providing buttresses at certain intervals
31 In the case of panel wall subjected to horizontal loads at right angles to the plane of the wall, with the mortar not leaner than Ml type, tensile stress in bending in the vertical direction may be allowed to the extent of
A 0.4 kg/cm2
B 0.7 kg/cm2
C 1.0 kg/cm2
D 1.2 kg/cm2

Answer: 1.0 kg/cm2
32 Consider the following statements : The use of relatively weak mortar

1. will accommodate movements due to loads and, cracking if any, and will be distributed as thin hair cracks which are less noticeable or harmful.

2. will result in reduction of stresses due to differential expansion of masonry units.

Of these statements
A 1 alone is correct
B 2 alone is correct
C both 1 and 2 are correct
D neither 1 nor 2 is correct

Answer: both 1 and 2 are correct
33 Consider the following statements regarding provision of chases in masonry,

(i) No chase should be permitted in a half brick load-bearing wall,

(ii) Vertical chases should not be closer than 2 m in any stretch of a wall,

(iii) Chases should be provided near to bearings of beams and lintels. Of these statements

A (i) and (ii) are correct
B (i) and (iii) are correct
C (ii) and (iii) are correct
D (i), (ii) and (iii) are correct

Answer: (i) and (ii) are correct
34

Assertion A : Limiting value of slenderness ratio for a column is less than that of a wall.

Reason R : A column can buckle around either of the two horizontal axes while a wall can buckle around only one axis.

Select your answer according to the codes given below:
A Both A and R are true and R is the correct explanation of A.
B Both A and R are true but R is not the correct explanation of A.
C A is true but R is false.
D A is false but R is true.

Answer: Both A and R are true and R is the correct explanation of A.
35 In a cavity wall, both leaves of which are load bearing, the effective thickness is taken as
A sum of thickness of both leaves
B two-third of the sum of thickness of both the leaves
C actual thickness of the stronger leaf
D larger of (b) and (c)

Answer: larger of (b) and (c)
36 Consider the following statements regarding bands to be provided for strengthening masonry work in masonry buildings constructed in zone III, IV and V. (i) Lintel band is provided at lintel level on partition walls, (ii) Gable band is provided at top of gable masonry below the purlins, (iii) The bands shall be to full width of the wall and not less than 7.5 cm in depth, (iv) The bands shall be made of reinforced concrete only. Of these statements, the correct statements are
A (i) and (ii)
B (i) and (iii)
C (ii) and (iv)
D (ii) and (iii)

Answer: (ii) and (iii)
37 For earthquake resistant masonry buildings, where seismic coefficient is less than 0.08, the horizontal distance between two openings shall not be less than
A Vt x height of shorter opening
B Vt x height of longer opening
C Ax height of shorter opening
D Vi x height of longer opening

Answer: Vt x height of shorter opening
38 For earthquake resistant masonry buildings, the vertical distance between openings one above the other in a load bearing wall shall not be less than
A 50 cm
B 60 cm
C 75 cm
D 100 cm

Answer: 60 cm
39 Rich cement mortars are more liable to cracking as compared to lean mortars because rich mortars have
A high shrinkage
B less strength
C both (a) and (b)
D none of above

Answer: high shrinkage
40 Minimum compressive strength in N/mm2 for H1 type mortar used for masonry is
A 3
B 5
C 7.5
D 10

Answer: 10

ADRE 2.0 FULL LENGTH MOCK TEST

Take Mock Tests

Missiles Mock Test Start Test!
SSC MTS Mock Test Start Test
IBPS CLERK MOCK TEST Start Test
SSC MTS 2022 JULY 26 Shift 1 (ENGLISH) Start Test!
SSC GD Previous Year Paper 2021 Nov 17 Shift - I (Hindi) Start Test!
SSC CGL Tier - 1 PYP 2022 April 21 Shift- 1 (ENGLISH) Start Test!
MPSC PAPER I MOCK TEST 1 (ENGLISH) Start Test!
IB Security Assistant Mock test 1 (english) Start Test!
UP POLICE CONSTABLE MOCK TEST 1 Start Test!
DELHI POLICE CONSTABLE MOCK TEST 1 (HINDI) Start Test!
Advertisement
Assam Direct Recruitment Test Series

Latest Test Series

ssc cgl test series

SSC CGL

Start Test 1000+ Tests Latest patternView Course
delhi policesi test series

DELHI POLICE SI

Start Test 1000+ Tests Latest patternView Course
west bengal psc test series

WEST BENGAL PSC

Start Test 1000+ Tests Latest patternView Course
cisf head constable test series

CISF CONSTABLE

Start Test 1000+ Tests Latest patternView Course
Junior Associate of the Indian Institute of Bankers(JAIIB) test series

JAIIB

Start Test 30 Full Length Tests View Course
adre 2024 test series

ADRE 2024

Start Test 25000+ QUESTIONS SOLUTIONSView Course
RRB RRC GROUP D test series

RRB RRC GROUP D

Start Test 15000+ QUESTIONS Latest patternView Course
UP POLICE SI test series

UP POLICE SI

Start Test 16000+ QUESTIONS Latest patternView Course
CLICK HERE TO VIEW ALL COURSES