21 Most commonly used indicator electrode is
A Glass electrode
B Silver – Silver chloride electrode
C Calomel electrode
D Silver electrode

Answer: Glass electrode
22 Test electrode is also known as
A Indicator electrode
B Reference electrode
C Second electrode
D Primary electrode

Answer: Indicator electrode
Advertisement
Article and Schedule Quiz Start Test!

DOWNLOAD CURRENT AFFAIRS PDF FROM APP

23

S1: In multimode fiber optics, intensity modulating schemes can be employed.

S2: Schemes using polarizing techniques need birefringent fiber.

A S1 is true and S2 is false
B Both S1 and S2 are true
C S1 is false and S2 is true
D Both S1 and S2 are false

Answer: Both S1 and S2 are true
24 Photo conductive cell consists of a thin film of
A Selenium
B Barium titanate
C Quartz
D Lithium sulphate

Answer: Selenium
25 In foil strain gauge the thickness of foil varies from
A 2.5 micron to 6 micron
B 2.5 micron to 5 micron
C 25 micron (or) less
D 25 micron to 60 micron

Answer: 2.5 micron to 6 micron
26 The change in resistance of a metal wire owing to strain is due to

S1: Change in dimension of wire expressed by factor (1-2µ)

S2: Change in resistance ??

A S1 is true & S2 is false
B S2 is true & S1 is false
C Both S1 & S2 are true
D Both S1 & S2 are false

Answer: S2 is true & S1 is false
27 Pressure transducer for measuring blood pressure is
A Strain gauge transducer only
B Strain gauge or capacitive transducer
C Resistive transducer
D Fiber optic transducer

Answer: Strain gauge or capacitive transducer
28 Venturi is associated with
A Venous blood pressure
B Digital plethysmography
C Dialysate flow in artificial kidney
D Blood flow in heart lung machine

Answer: Blood flow in heart lung machine
29 The application of LVDT is
A Joint motion
B Finger movement
C Limb movement
D Heart wall motion

Answer: Limb movement
30 The principle of operation of variable resistance transducer is
A Deformation leads to change in resistance
B Displacement of a contact slider on a resistance
C Coupling of two coils changes with displacement
D Movement of magnetic field produces variation in resistance of material

Answer: Displacement of a contact slider on a resistance
31 The transducers which requires an external power and their output is a measure of some variation such as resistance, inductance, capacitance etc., are called as
A Active transducer
B Primary sensor
C Passive transducer
D Self generating transducer

Answer: Passive transducer
32 Pick the correct statement regarding functions of a transducer

S1: Sense the magnitude, change in & / or frequency of same measurand

S2: To provide electrical output that furnishes accurate, quantitative data about the measurand

A S1 is true & S2 is false
B S2 is true & S1 is false
C Both S1 & S2 are true
D Both S1 & S2 are false

Answer: Both S1 & S2 are true
33 Capacitive transducers are normally employed for___________ measurements
A Static
B Dynamic
C Transient
D Both static and dynamic

Answer: Dynamic
34 In a LVDT, the two secondary voltages
A Are independent of the core position
B Vary unequally depending on the core position
C Vary equally depending on the core position
D Are always in phase quadrature

Answer: Vary unequally depending on the core position
35 S1: Transducer is a device which converts physical into electrical quantity S2: Transducer is also called as sensor.
A S1 is true & S2 is false
B S2 is true & S1 is false
C Both S1 & S2 are true
D Both S1 & S2 are false

Answer: S2 is true & S1 is false
36 Which of the following can be measured with the help of piezo electric crystal?
A Force
B Velocity
C Sound
D Pressure

Answer: Force
37 LVDT is an/a ___________ transducer
A Eddy current
B Resistive
C Magneto-strict ion
D Inductive

Answer: Eddy current
38 _____________ is the example of photo emissive cell
A LDR
B Photo diode
C Photo transistor
D Photo multiplier

Answer: LDR
39 pH value of venous blood is
A 7.30
B 7.40
C 7.35
D 7.45

Answer: 7.35
40 Silver chloride electrode is used as a reference electrode due to its
A Large half cell potential
B Stable half cell potential
C Stable resting potential
D Stable action potential

Answer: Stable half cell potential

ADRE 2.0 FULL LENGTH MOCK TEST

Take Mock Tests

Missiles Mock Test Start Test!
SSC MTS Mock Test Start Test
IBPS CLERK MOCK TEST Start Test
SSC MTS 2022 JULY 26 Shift 1 (ENGLISH) Start Test!
SSC GD Previous Year Paper 2021 Nov 17 Shift - I (Hindi) Start Test!
SSC CGL Tier - 1 PYP 2022 April 21 Shift- 1 (ENGLISH) Start Test!
MPSC PAPER I MOCK TEST 1 (ENGLISH) Start Test!
IB Security Assistant Mock test 1 (english) Start Test!
UP POLICE CONSTABLE MOCK TEST 1 Start Test!
DELHI POLICE CONSTABLE MOCK TEST 1 (HINDI) Start Test!
Advertisement
Assam Direct Recruitment Test Series