JOIN ADRE 2.0 Telegram Group

Synchronous Motor Quiz | Synchronous Motor Short Questions and Answers

Questions
41 In a synchronous motor running with fixed excitation, when the load is increased three times, its torque angle becomes approximately
A One-third
B Twice
C Thrice
D Nine times

Answer: Thrice
42 The operating speed of a synchronous motor can be changed to new fixed value by
A Changing the load
B Changing the supply voltage
C Changing frequency
D Using brakes

Answer: Changing frequency
Advertisement
Article and Schedule Quiz Start Test!

DOWNLOAD CURRENT AFFAIRS PDF FROM APP

43 The speed regulation of a synchronous motor is always
A 1%
B 0.5%
C Positive
D Zero

Answer: Zero
44 While running, a synchronous motor is compelled to run at synchronous speed because of
A Damper winding in its pole faces
B Magnetic locking between stator and rotor poles
C Induced e.m.f. in rotor field winding by stator flux
D Complusion due to Lenz's law

Answer: Magnetic locking between stator and rotor poles
45 In a synchronous motor, damper winding is provided in order to
A Stabilize rotor motion
B Suppress rotor oscillations
C Develop necessary starting torque
D Both (a) and (c)

Answer: Both (a) and (c)
46 In a synchronous motor, the rotor Cu losses are met by
A Motor input
B Armature input
C Supply lines
D D.C. source

Answer: D.C. source
47 The armature current of the synchronous motor has higher values for
A High excitation only
B Low excitation only
C Both (a) and (b)
D None of the above

Answer: Both (a) and (b)
48 The synchronous motor is not inherently self-starting because
A The force required to accelerate the rotor to the synchronous speed in an instant is absent
B The starting device to accelerate the rotor to near synchronous speed is absent
C A rotating magnetic field does not have enough poles
D The rotating magnetic field is produced by only 50 Hz frequency currents

Answer: The force required to accelerate the rotor to the synchronous speed in an instant is absent
49 A synchronous motor can be made self-starting by providing
A Damper winding on rotor poles
B Damper winding on stator
C Damper winding on stator as well as rotor poles
D None of the above

Answer: None of the above
50 Synchronous motors are generally not self-starting because
A The direction of rotation is not fixed
B The direction of instantaneous torque reverse after half cycle
C Startes cannot be used on these machiness
D Starting winding is not provided on the machines

Answer: The direction of instantaneous torque reverse after half cycle

ADRE 2.0 FULL LENGTH MOCK TEST

Take Mock Tests

Missiles Mock Test Start Test!
SSC MTS Mock Test Start Test
IBPS CLERK MOCK TEST Start Test
SSC MTS 2022 JULY 26 Shift 1 (ENGLISH) Start Test!
SSC GD Previous Year Paper 2021 Nov 17 Shift - I (Hindi) Start Test!
SSC CGL Tier - 1 PYP 2022 April 21 Shift- 1 (ENGLISH) Start Test!
MPSC PAPER I MOCK TEST 1 (ENGLISH) Start Test!
IB Security Assistant Mock test 1 (english) Start Test!
UP POLICE CONSTABLE MOCK TEST 1 Start Test!
DELHI POLICE CONSTABLE MOCK TEST 1 (HINDI) Start Test!
Advertisement
Assam Direct Recruitment Test Series