1 The insulating material for a cable should have
A high mechanical strength
B low cost
C high dielectric strength
D all of the above

Answer: all of the above
2 Which of the following insulation is used in cables ?
A Paper
B Varnished cambric
C Rubber
D Any of the above

Answer: Any of the above
Advertisement
Article and Schedule Quiz Start Test!

DOWNLOAD CURRENT AFFAIRS PDF FROM APP

3 In a cable immediately above metallic sheath _____ is provided.
A Armouring
B Earthing Connection
C Bedding
D None Of The Above

Answer: Bedding
4 In single core cables armouring is not done to
A avoid excessive sheath losses
B make it flexible
C either of the above
D none of the above

Answer: avoid excessive sheath losses
5 Dielectric strength of rubber is around
A 200 kV/mm
B 30 kV/mm
C 5 kV/mm
D 15 kV/mm

Answer: 30 kV/mm
6 PVC stands for
A post varnish conductor
B positive voltage conductor
C polyvinyl chloride
D None of the above

Answer: polyvinyl chloride
7 In the cables, the location of fault is usually found out by comparing
A the inductance of conductors
B the capacitances of insulated conductors
C the resistance of the conductor
D all above parameters

Answer: the capacitances of insulated conductors
8 The relative permittivity of rubber is
A between 2 and 3
B between 5 and 6
C between 8 and 10
D between 12 and 14

Answer: between 2 and 3
9 Solid type cables are considered unreliable beyond 66 kV because
A there is a danger of breakdown of insulation due to the presence of voids
B of corona loss between conductor and sheath material
C insulation may melt due to higher temperature
D skin effect dominates on the conductor

Answer: there is a danger of breakdown of insulation due to the presence of voids
10 In cables the charging current
A leads the voltage by 90°
B leads the voltage by 180°
C lags the voltage by 90°
D lags the voltage by 180°

Answer: leads the voltage by 90°
11 In the cables, sheaths are used to
A prevent the moisture from entering the cable
B provide proper insulation
C provide enough strength
D None Of The Above

Answer: prevent the moisture from entering the cable
12 In a cable the voltage stress is maximum at
A core of the conductor
B surface of the conductor
C sheath
D insulator

Answer: core of the conductor
13 Underground cables are laid at sufficient depth
A to avoid being unearthed easily due to removal of soil
B to minimise the effect of shocks and vibrations due to gassing vehicles, etc.
C for all of the above reasons
D to minimise temperature stresses

Answer: to minimise the effect of shocks and vibrations due to gassing vehicles, etc.
14 The thickness of metallic shielding on cables is usually
A 0.04 mm
B 40 to 60 mm
C 0.2 to 0.4 mm
D None Of The Above

Answer: 0.04 mm
15 The underground system is ...........costly then the equivalent overhead line system
A Greater than
B Less
C More
D Same

Answer: More
16 Metallic shielding is provided on underground cables to
A Control the electrostatic voltage stress
B Reduce thermal resistance
C Reduce corona effect
D All of the above

Answer: All of the above
17 The materials used for armouring of an underground cable is
A Galvanised steel wire
B Steel tape
C Aluminium
D Either A or B

Answer: Either A or B
18 In underground cables the electrostatic stress is
A Zerothe contactor as well as on the sheath
B Minimum at contactor surface and maximum at the sheath
C Maximum at contactor surface and minimum at the sheath
D Same at the conductor and sheath

Answer: Maximum at contactor surface and minimum at the sheath
19 Underground cables are laid at sufficient depth so as to
A Minimise temperature stresses
B Minimise effects of shocks and vibrations owing to passing vehicles etc.
C Avoid being unearthed easily owing to removal of soil
D Both A and C

Answer: Minimise effects of shocks and vibrations owing to passing vehicles etc.
20 A layer similar to bedding is provided on the armouring to protect the whole cable from all atmospheric conditions. Which layer is this?
A Serving.
B Sheath
C Insulation
D A layer of jute

Answer: Serving.

ADRE 2.0 FULL LENGTH MOCK TEST

Take Mock Tests

Missiles Mock Test Start Test!
SSC MTS Mock Test Start Test
IBPS CLERK MOCK TEST Start Test
SSC MTS 2022 JULY 26 Shift 1 (ENGLISH) Start Test!
SSC GD Previous Year Paper 2021 Nov 17 Shift - I (Hindi) Start Test!
SSC CGL Tier - 1 PYP 2022 April 21 Shift- 1 (ENGLISH) Start Test!
MPSC PAPER I MOCK TEST 1 (ENGLISH) Start Test!
IB Security Assistant Mock test 1 (english) Start Test!
UP POLICE CONSTABLE MOCK TEST 1 Start Test!
DELHI POLICE CONSTABLE MOCK TEST 1 (HINDI) Start Test!
Advertisement
Assam Direct Recruitment Test Series